Silent Knight 5808 Programming Manual: Article Plan
This document details programming the Silent Knight 5808 fire alarm control panel, utilizing SKSS software and a modem for efficient configuration and system customization.

The Silent Knight 5808 is a versatile and powerful fire alarm control panel designed for a wide range of applications, from small commercial buildings to large complexes. Its robust design and advanced features ensure reliable fire detection and notification. Programming the 5808 is crucial for tailoring the system to specific site requirements, including zone configurations, device settings, and alarm reporting protocols.
Effective programming allows technicians to optimize system performance, minimize false alarms, and ensure rapid response in emergency situations. The panel supports both on-board programming via its keypad and off-board programming using Silent Knight’s SKSS software, offering flexibility and convenience. Understanding the programming structure and available options is key to maximizing the 5808’s capabilities.
Understanding SKSS Programming Software

SKSS (Silent Knight System Software) is an optional, Windows-based software package that significantly simplifies the programming process for the 5808 fire alarm control panel. Unlike keypad programming, SKSS offers a graphical user interface (GUI) for intuitive navigation and configuration. It allows technicians to create, edit, and download system settings directly to the panel via a modem connection.
SKSS streamlines complex tasks like zone definitions, device assignments, and cause-and-effect matrix creation. The software provides real-time feedback and error checking, reducing the risk of misconfiguration. While a modem is required (and not supplied by Silent Knight), SKSS dramatically improves programming efficiency and accuracy, especially for larger or more intricate systems.

Required Equipment for Programming
Successfully programming a Silent Knight 5808 control panel necessitates specific equipment. Primarily, a Windows-compatible computer is essential for running the SKSS programming software. A functional modem is crucial for establishing communication between the computer and the fire alarm panel – Silent Knight does not include one with the software.
Beyond these core components, a standard telephone line is needed for modem connectivity. Ensure the line is clear and dedicated to avoid interference during downloads. A serial cable (RS-232) will connect the modem to the computer. Finally, access to the panel’s physical interface is required for initial setup and verification of programmed settings.
Computer Requirements
To effectively utilize the SKSS programming software with a Silent Knight 5808 panel, your computer must meet certain specifications. A Windows-based operating system is mandatory, with compatibility extending across various versions – though newer versions are generally recommended for optimal performance and security updates.
A minimum of 32MB of RAM is suggested, however, 64MB or greater will significantly improve software responsiveness. Sufficient hard drive space – at least 50MB – is needed for software installation and data storage. A standard serial port (RS-232) is essential for modem connection. Finally, a reliable power supply is crucial to prevent interruptions during the programming process.
Modem Compatibility
The Silent Knight 5808 panel utilizes a modem for off-site programming via the SKSS software. Compatibility isn’t limited to specific brands, but certain specifications are vital for reliable communication. A Hayes-compatible modem is required, supporting V.32 or higher communication protocols for faster data transfer speeds.
Ensure the modem operates at 1200 to 9600 baud rates, with adjustable settings to optimize connection quality. Internal or external modems can be used, but external modems often offer greater flexibility. Proper modem configuration, including initialization strings, is crucial for establishing a successful link with the fire alarm control panel during the programming sequence.
Accessing the Programming Menu
To initiate programming on the Silent Knight 5808, you must first gain access to the dedicated programming menu. This is achieved by entering the correct installer code directly into the control panel’s keypad. The system is designed with security in mind, restricting access to authorized personnel only.
Upon powering up or resetting the panel, the display will prompt for entry. Accurate input is essential; incorrect attempts may trigger a security lockout. Once the code is accepted, the panel will guide you through navigating to the Main Menu, which serves as the gateway to all programming functions and system configurations.
Entering the Installer Code
Initiating access to the programming functions requires entering the installer code via the control panel’s keypad. This six-digit code acts as a security measure, preventing unauthorized modifications to the system’s configuration. Ensure accurate entry, as multiple incorrect attempts can temporarily lock you out of the programming menu.
The system will display a prompt requesting the installer code. Carefully input the digits, confirming each entry before proceeding. Successful entry unlocks the Main Menu, providing access to various programming options. Remember to document the code in a secure location for future reference, should the need arise for system adjustments or maintenance.
Default Installer Code (123456)
Upon initial installation, the Silent Knight 5808 control panel is pre-programmed with a default installer code: 123456. This allows immediate access to system programming for initial setup and configuration. However, for enhanced security, it is crucially important to change this default code immediately after completing the initial setup process.
Leaving the default code in place presents a significant security risk, potentially allowing unauthorized individuals to alter critical system settings. To modify the code, navigate to the appropriate programming menu option and follow the on-screen prompts. Choose a unique, memorable code, and store it securely, separate from the system documentation;

Navigation within the Programming Menu
Once you’ve entered the valid installer code, the Silent Knight 5808 presents a hierarchical menu structure for programming. Utilize the keypad to scroll through options, typically using the up and down arrow keys. Selecting a menu item is generally achieved by pressing the ‘Enter’ or ‘#’ key.
Pay close attention to the on-screen prompts; the display guides you through each level of the menu. Backtracking to previous menus is often done with a ‘Cancel’ or ‘*’ key. Remember to save any changes made within each programming section to ensure they are implemented. Careful navigation is key to avoiding unintended alterations to the system’s configuration.
Programming Methods & Data Entry
The Silent Knight 5808 offers multiple methods for programming, including direct keypad entry and, optionally, through SKSS software connected via modem. Keypad entry involves navigating the menu and inputting values using the numeric keys. Data entry often requires understanding specific field formats – numbers, dates, or selections from predefined lists.
When using SKSS, the process becomes more visual and streamlined. The software provides a user-friendly interface for configuring all system parameters. Regardless of the method, always double-check entered data for accuracy before saving. Incorrect values can lead to system malfunctions or false alarms during programming.
Key Programming Functions
The Silent Knight 5808’s core programming capabilities center around zone and device configuration. Zone programming defines the characteristics of each detection circuit – normal, alarm, or trouble states – and associated notification appliances. Device programming configures individual detectors, modules, and other peripherals, assigning them to zones and setting specific operational parameters.
Further essential functions include setting system constants, communication protocols, and alarm verification rules. Proper configuration of these elements is crucial for reliable fire detection and notification. Understanding these key programming areas ensures the system operates as intended, providing optimal protection and minimizing false alarms.
Zone Programming
Zone programming within the Silent Knight 5808 defines each detection circuit’s behavior. This includes assigning a zone type – such as notification, supervisory, or alarm – and configuring its response to alarm conditions. Crucially, you’ll set the zone’s normal, alarm, and trouble states, dictating how the panel interprets sensor input.
Further customization involves enabling or disabling cross-zoning, setting alarm verification timers, and defining associated notification appliances. Proper zone configuration is vital for accurate fire detection and appropriate response. Careful consideration of each zone’s purpose and environment ensures reliable system operation and minimizes false alarms.

Device Programming
Device programming configures individual components connected to the Silent Knight 5808, like detectors, modules, and notification appliances. This involves assigning device types, addresses, and sensitivity levels. For detectors, you’ll set parameters influencing alarm thresholds and sensitivity to various stimuli, minimizing false activations.
Modules require programming to define their input/output configurations and associated zones. Notification appliances are programmed for synchronization and activation patterns. Accurate device programming ensures each component functions correctly within the system. Proper configuration is essential for reliable fire detection, notification, and overall system performance.

Common Programming Tasks
Frequently performed programming tasks on the Silent Knight 5808 include zone definition – assigning specific areas to detectors and notification devices. Adjusting alarm sensitivity levels to reduce false alarms while maintaining reliable detection is crucial. Configuring communication settings for off-site monitoring is also common, ensuring prompt emergency response.
User access code management, adding or deleting users with varying permission levels, enhances security. Programming relay outputs for auxiliary functions, like door unlocking, is often needed. Regularly reviewing and updating system programming ensures optimal performance and compliance with safety standards. These tasks maintain a robust and responsive fire alarm system.
Troubleshooting Programming Issues
Common programming problems with the Silent Knight 5808 often involve communication errors between the control panel and the SKSS software, typically due to modem incompatibility or incorrect settings. Incorrect installer codes can lock you out of the programming menu; remember the default is 123456. Data entry errors, like typos in zone names or device addresses, can cause malfunctions.
If the system fails to respond, verify power connections and modem functionality. Corrupted programming files can necessitate a factory reset and reprogramming. Always document changes and back up configurations. Consulting the manual or contacting Silent Knight support can resolve complex issues efficiently, ensuring system reliability.
Carbon Monoxide Detector Programming
Programming CO detectors on the Silent Knight 5808 requires careful attention to sensitivity settings. These determine the CO concentration triggering an alarm, balancing responsiveness with false alarm prevention. Configure alarm reporting configuration to ensure proper notification to monitoring stations or occupants upon CO detection.
The system allows customization of alarm thresholds and reporting protocols. Regularly test CO detectors to verify functionality. Understanding CO’s odorless, tasteless, and colorless nature is crucial. Proper programming ensures swift alerts, protecting against potentially fatal carbon monoxide poisoning from fuel-burning appliances.
Sensitivity Settings
Adjusting sensitivity for carbon monoxide (CO) detectors on the Silent Knight 5808 is critical for reliable performance. Lower settings reduce false alarms but may delay detection of dangerous CO levels. Higher settings increase sensitivity, potentially leading to nuisance alarms from minor CO sources.
The panel allows programming different sensitivity levels, typically expressed in parts per million (PPM). Consider the environment when setting sensitivity; homes with fuel-burning appliances require more cautious settings. Regularly review and adjust these settings based on observed performance and local regulations, ensuring optimal protection against CO poisoning.

Alarm Reporting Configuration
Configuring alarm reporting on the Silent Knight 5808 ensures prompt notification of fire or CO emergencies. The panel supports various communication methods, including traditional phone lines and IP-based reporting via network connections. Programming involves defining the central station account number, communication format, and alarm signal priority.
Proper configuration dictates how and to whom alarms are relayed. Options include immediate reporting, callback verification, and detailed zone information transmission. Regularly test the reporting pathway to confirm functionality and adherence to local regulations. Accurate programming is vital for a swift and effective emergency response.
Silent Heart Attack Detection Integration (If Applicable)
Integration with silent heart attack detection systems, while not standard, can be achieved through specialized input modules and custom programming on the Silent Knight 5808. This requires interfacing with external sensors capable of detecting physiological indicators associated with such events.
Programming involves assigning a dedicated zone input to the detection system and configuring appropriate alarm responses. Critical considerations include sensitivity adjustments to minimize false alarms and ensuring reliable signal transmission. Proper integration necessitates a thorough understanding of both the fire alarm panel and the external detection technology, alongside adherence to relevant safety standards.
Reflux Sensor Integration (If Applicable)
Integrating reflux sensors with the Silent Knight 5808 is unconventional, as the panel isn’t designed for medical monitoring. However, specialized detectors could theoretically trigger an alarm via a conventional zone input, requiring custom programming. This would involve assigning a zone to the sensor and configuring the desired alarm response – likely a supervisory or auxiliary alarm.
Programming must account for potential false alarms, as reflux events aren’t life-threatening emergencies. Sensitivity settings and alarm verification protocols are crucial. Remember, this application deviates from the panel’s intended use and requires careful consideration of liability and regulatory compliance.
Programming for System Diagnostics
The Silent Knight 5808 offers robust diagnostic capabilities accessible through programming. Enabling detailed event logging is paramount, capturing zone activations, trouble conditions, and system events with timestamps. Configure the panel to report specific diagnostic data – battery voltage, communication status, and sensor readings – to a central monitoring station.
Utilize walk test programming to simulate activations and verify proper system response. Regularly scheduled diagnostic tests, programmed via the SKSS software, can proactively identify potential issues. Reviewing logged events helps pinpoint intermittent problems and optimize system performance, ensuring reliable fire detection and notification.
Advanced Programming Options
The Silent Knight 5808 provides advanced programming features for experienced technicians. Customize sensitivity levels for individual detectors, tailoring response to specific environments and minimizing false alarms. Configure cross-zoning options to require multiple zone activations for alarm verification, enhancing reliability.
Explore advanced reporting options, including detailed event logging and customized alarm messages. Program unique user access codes with varying permission levels for enhanced security. Utilize the panel’s ability to integrate with other building systems, such as HVAC controls, for automated emergency responses. These options require a thorough understanding of fire alarm system principles.
Restoring Factory Defaults
Restoring the Silent Knight 5808 to factory defaults erases all custom programming, returning the panel to its original settings. This is useful for troubleshooting, system resets, or when preparing the panel for a new installation. Caution: This action is irreversible without specialized tools and knowledge.
Typically, restoring defaults involves a specific key sequence entered through the keypad while in programming mode. Consult the full installation manual for the precise procedure, as it may vary depending on the firmware version. Always document existing programming before performing a factory reset to facilitate re-configuration. Verify proper operation after the reset.
Programming Security Considerations
Maintaining system security is paramount when programming the Silent Knight 5808. The default installer code (123456) must be changed immediately upon initial setup. Utilize a complex, unique code and keep it confidential. Limit access to programming functions to authorized personnel only.
Regularly review programmed settings to ensure accuracy and prevent unauthorized modifications. Consider enabling advanced security features, if available, such as user-specific access levels. Document all programming changes with dates and initials; Secure the physical panel location to prevent tampering. A compromised system can lead to false alarms or, critically, system failure during an emergency.
Frequently Asked Programming Questions
Q: I forgot the installer code – what do I do? A: Contact Silent Knight support for assistance; a factory reset may be required, erasing all custom programming. Q: Can I program remotely without a modem? A: No, SKSS software requires a compatible modem for remote access. Q: How do I update the panel’s firmware? A: Firmware updates are typically performed via SKSS software – consult the latest documentation.

Q: What if a zone consistently triggers false alarms? A: Review zone sensitivity settings and investigate potential causes of interference. Q: Is there a limit to the number of devices I can program? A: Refer to the panel’s specifications for maximum device capacity.
Resources and Support
For comprehensive documentation, visit the Silent Knight website to download the latest installation and programming manuals for the 5808 panel and SKSS software. Access detailed guides, technical bulletins, and frequently asked questions to aid in troubleshooting and configuration.
Silent Knight’s technical support team is available via phone and email to assist with complex programming issues or system errors. Additionally, numerous online forums and communities dedicated to fire alarm systems offer peer-to-peer support and valuable insights. Consider enrolling in Silent Knight’s training programs for in-depth knowledge.